C-10
2. In the fourth column, write down the lengths of the SCSI-2
interconnect cables you are using for your installation. (Cable
lengths are listed in subsection “Cables” in the section on “SCSI
Restrictions.”)
3. Add up all of the numbers in the third column and write that
number on the subtotal line at the bottom of the column. Do the
same for the fourth column.
4. Add the subtotals together and write the total in the Total SCSI-2
Bus Length box.
NOTICE: The total length of the single-ended standard
SCSI-2 bus must not exceed 6 meters (19.6
feet). If the number you write for Total SCSI-2
Bus Length is greater than 6 meters (19.6 feet),
try configuring your installation with shorter
cables.
If you have problems, call your designated service representative.